STERLINK FPS-15s Plus
FPS-15s Plus
Low Temperature Plasma Sterilizer for
Wide Range of Medical Devices
The world’s first direct injection pouch-type patented sterilization technology has been applied.
SAL of 10-6 is validated to ensure sterilization stability of medical devices.
(SAL: Sterility Assurance Level, 99.9999%)
Sterilization Performance
STERLINK verifies sterilization performance through the following lumen tests
 
Single-channel lumen claims for STERLINK
  • Ø0.7 x 500mm Stainless steel
  • Ø2.0 x 1,500mm Stainless steel
  • Ø1.0 x 2,000mm PTFE
STERLINK - inside diameter 1mm and a length up to 2,000mm
Competitor A
length up to 500mm
Competitor B
length up to 1,000mm
Plasmapp
STERLINK


Low Temperature
Sterilization


Easy
Operation


Fast
Sterilization


Compact
Design


Lumen
Sterilization


Real-Time
Monitoring

The world's first small plasma sterilizer
approved by the US FDA
510(K) clearance for STERLINK sterilizer system of Plasmapp
(K212200 / K212193 / K212198)

Specification
STERLINK FPS-15s Plus
Size(W x D x H) 433 x 614 x 437 mm Vacuum Pump Pump built-in type
Chamber(W x D x H) 264 x 410 x125 mm(14ℓ) Weight 67kg
Chamber Diagonal Length 47cm Sterilant Cassette 1 Cycle
STERMATE Sterilant
Introducing the Sterilant used with the STERLINK FPS-15s Plus

STERPACK
Pouch Mode
1 Cycle Use Only

STERPACK plus
Pouch Plus Mode
1 Cycle Use Only

STERLOAD
Chamber Mode
1 Cycle Use Only
Pouch / Pouch Plus Mode
  • World first pouch-type fast sterilization with the patented direct sterilant injection technology from Plasmapp.
  • Vacuum condition visualizes the sterile condition and prevents possible infection.
  • Vacuum sealed pouch can be stored up to 6 months in sealed sterile condition.
  • STERPACK can easily be loaded into the chamber by an ergonomically designed.
  • STERPACK does not leave sterile residue, so the chamber can be kept clean.
Chamber Mode
  • Medical instruments in the 14 liter chamber are sterilized in a short time.
  • Sterilant is contained inside the cartridge which prevents any hazard from chemical exposure.
  • Use Tyvek® for easy storage after using chamber mode.
Cycle Time
Mode Cycle Time Capacity Sterilant
Pouch Mode STERPACK : 7 min 1ℓ H2O258% - 59.5%
(0.1ml/cell)
Pouch Plus Mode STERPACK Plus : 14 min 4.5ℓ H2O258% - 59.5%
(0.3ml/cell)
Chamber Mode STERLOAD : 36 min 14ℓ H2O258% - 59.5%
(0.9ml/cell)
* STERPACK, STERPACK Plus and STERLOAD are global certified sterilant.
Innovative plasma sterilization technology verified
through patents and research papers
Forced convective heating for low-temperature sterilization
Publication expected in 2021 (AIP) - https://doi.org/10.1063/5.0048688
Review of Scientific Instruments 92, 064902 (2021) conducted by Dr. Youbong Lim, Dr. Wonho Choe, Dr. Seung Hun Lee, Dr. Jun Young Kim and Dr. Hyun Jeong Jeon